Trusted by 27+ Customers ★★★★★ ★★★★★ 4.6 out of 5

UV Air Filtration System | Crystal Quest Micro-Blaster 125 or 250 Watt

Crystal Quest SKU: CQE-UVX-0125

Adds flexible UV air treatment to offices and homes without adding chemical disinfectants to the space.

Price
Regular price $3,07500
Regular price Sale price $3,07500
Save $-3,075
/
Size
  • In stock, ready to ship
  • Backordered, shipping soon
Shipping, Returns, & Warranties

Orders Processing: We offer fast and reliable shipping across the continental U.S., with free shipping available on orders over $200 (exclusions may apply based on brand and product type). Orders are typically processed within 1–2 business days and transit time is 4–8 business days. Larger items may ship via freight and require a scheduled curbside delivery. Please ensure your contact details are accurate at checkout. For questions about delivery timelines, shipping eligibility, or special requests, feel free to contact us directly.

Order Confirmation: As soon as you place your order, you will receive an order confirmation e-mail.  This means that we have received your order in our system.

30 Day Returns: If your order arrives damaged, we will exchange you a replacement. Our return policy cover from the date of purchase. To be eligible, items must be unused, in their original packaging, and accompanied by proof of purchase. Defective products are eligible for free returns, with options for a refund or replacement. Customer remorse returns may incur return shipping fees and restocking fees. Refunds are processed within a specified timeframe, subject to restocking fees if applicable. Late or missing refunds should be addressed with your bank or credit card company first. Exchanges may be accepted for defective or damaged items. Shipping costs for returns are typically the responsibility of the customer, except in cases of damaged products. For more details, visit our Refund Policy Page.

View our Full Brand Warranty Page Here

Request a quote

Mobile ultraviolet air treatment

UV air treatment for indoor residential and office spaces

The Crystal Quest Micro-Blaster Ultraviolet Air Filtration System draws room air into an enclosed chamber and exposes it to germicidal ultraviolet light before returning the air to the surrounding space. Choose the 125 watt Mobile X or 250 watt Mobile XL based on the model required for your application.

The mobile housing can also be wall mounted. UV treatment works without adding chemical disinfectants to the room.

Crystal Quest Micro-Blaster Mobile X and Mobile XL ultraviolet air filtration system
125 or 250 wattsTwo mobile model options
Indoor usePortable or wall mounted placement
Internal airflowAir passes through the UV chamber
No chemicals addedUltraviolet treatment process

Practical benefits

Enclosed UV treatment with flexible placement

Internal air circulation

The built in airflow system draws surrounding air through the enclosed ultraviolet treatment chamber and returns it to the room.

No chemical disinfectants

Uses germicidal ultraviolet light without adding chemical disinfectants or treatment chemicals to the surrounding air.

Mobile or wall mounted

Portable construction supports flexible indoor placement, with wall mounting capability when a fixed location is preferred.

Best for

Who the Micro-Blaster is ideal for

Offices and shared work areas

Adds ultraviolet air treatment to indoor workplaces where flexible placement is useful.

Reception and service spaces

Suitable for planned UV treatment cycles in indoor reception areas, service rooms, and similar spaces.

Residential indoor spaces

Provides a mobile UV air treatment option for homes and apartments when the placement and safety requirements can be followed.

Treatment process

How the Micro-Blaster works

  1. Air enters the unit. The internal intake draws surrounding air into the housing.
  2. Air passes through the UV chamber. Germicidal ultraviolet lamps expose susceptible airborne microorganisms to UV energy.
  3. Air returns to the room. The internal airflow system releases the treated air back into the surrounding space.

The unit can be opened for surface treatment only when the area is vacant. Never expose people or pets to the internal ultraviolet lamps.

Crystal Quest Micro-Blaster ultraviolet air treatment unit and internal UV lamps

Verified model details

Mobile X and Mobile XL comparison

Comparison of Crystal Quest Micro-Blaster Mobile X and Mobile XL models
Model SKU UV power Placement
Mobile X CQE-UVX-0125 125 watts Mobile with wall mounting capability
Mobile XL CQE-UVX-0250 250 watts Mobile with wall mounting capability

Included equipment

  • Selected Micro-Blaster mobile UV air filtration unit
  • Power cord for an indoor electrical outlet

Product line construction and standards

  • Polycarbonate fire resistant housing
  • ISO 9001:2015 certified components
  • NEMA Type 3 and 3X standards
  • IEC IP55 standard

Setup and safe operation

Follow the UV manual before each treatment cycle

Inspect before use

Check the housing, lamps, power cord, and supplied parts for damage. Do not operate a damaged unit or a unit with broken, cracked, or shattered UV lamp glass.

Choose a safe location

Use indoors in an unoccupied area. Place the unit above or below eye level, keep it stable, and connect the power cord to the unit before plugging it into the outlet.

Limit each cycle

Operate for no more than 3 hours per treatment cycle. Allow at least 30 minutes of rest before the next cycle to help prevent internal damage.

Product documentation

Installation and operation guide

Crystal Quest ultraviolet air and surface sterilizer manual

Review the placement, operating cycle, open use, lamp, and ultraviolet safety requirements before using the system.

Open UV manual

Before you buy

Common Micro-Blaster questions

What is the difference between Mobile X and Mobile XL?

Mobile X is the 125 watt CQE-UVX-0125 model. Mobile XL is the 250 watt CQE-UVX-0250 model. Both are mobile indoor units with wall mounting capability.

Can the unit run continuously?

No. The UV manual limits operation to 3 hours per treatment cycle and requires at least 30 minutes of rest between cycles.

Can people or pets be present during open operation?

No. Open operation exposes the internal ultraviolet lamps and must occur only while the area is vacant. Direct or reflected UV light can damage the eyes and skin.

Does the system add chemicals to the air?

No. It uses ultraviolet light and does not add chemical disinfectants to the surrounding air.

Recently viewed